If no configuration is made, the Seeburger-Adapters will per default write their information into the default-trace / application log of the PI-System. 35 Years of Experience. September 9, 2005. Hi All, We are getting error while sending data from PI to 1SYNC(AS2 Receiver adapter). Follow RSS Feed Dear all, We have a scenario where, we are sending an IDOC from our SAP system via XI to one of our partner using AS2. de DE-75015 Bretten Phone: +49 (0) 7252 96 1443 B2B Routing Service: AS2 Data Sheet (Without TLS/SSL) Technical information to configure your AS2 connection to the SEEBURGER Cloud DATA SHEET Company Details. Involved in Designed SEEBURGER BIC mappings are E2X and X2E maps; Configured various adapters like SEEBURGER AS2, XI and JMS Adapter. Scenario-Description: 2 Customers that send edi-orders in the format ANSIX12_850_V4010, called “ElectronicWorld” and “GlobalElectronics”. The value for this field was being generated correctly in the message mapping, but was getting defaulted to zero when it was being converted to EDI, i. - Please check the AS2ID's very clearly. aii. In the field B2B Directory Entry, select the entry from or to which messages should be sent. 1EHP1, and since this upgrade we're having problems with the Seeburger AS2 adapter (2. The additional split configuration helps to map the Sender ID, (EDIType,Transaction,Version) combination to split channel and sender agreement. ResourceException: SEEBURGER AS2: 403 Forbidden # , SEEBURGER AS2: 403 Forbidden # I have configured the parties for the 2 systems that i am. The AS2 ID is unique and hence only one party can have partner’s AS2 ID. About SEEBURGER. Depth knowledge and hands on with XPATH, XML, XSLT, Java, ABAP and Graphical Mapping Tool. SEEBURGER AG AS2 Certificate Handling – How To Guide – Seite 8/21 19. 2. Seeburger AS2 adapter need to encrypt this messages and send to partner's AS2 server. R/3 system will send an Idoc to PI. I have check. And SSL are transprt layer security certificates, details of which needs to be given at the communication channel level. The SEEBURGER API Solution, as part of the Business Integration Suite, uses a single source-code base. Hi experts, We had a message in RWB with this error: Unable to forward message to JCA adapter. 1. For the connection is not SSL certificate on client side necessary. B2B AS2 Adapter - URL access without Credentials. 11 and 7. 2 Welcome to SMARTI - the framework for SEEBURGER web applications User: Password: Product info English • Deutsch : SEEBURGER B2B Portal. Your system to SEEBURGER. AS2 certificates are the message level security certificates. Its getting failed in Seeburger Monitor. Reason: Fatal exception: com. SEEBURGER provides Communication Service tools to handle the on-boarding and certificate complexity of AS2 and OFTP2 with ease. ,) and Idoc to EDIFACT (ORDERS,DESADV,INVOIC etc. Migration of existing Gentran (SI) system to SAP CrossGate then to SAP PI with Seeburger AS2 for EDI messages exchange between SAP ECC/CRM and EDI partners. SEEBURGER’s API connectivity and B2B/EDI capability will help M. Open the menu item Cloudlinks > Own Cloudlinks. 31/PO, Seeburger AS2 Adapter, IDOC,SFTP with Banking system EDI process for Austrlia Retail Grocery industry Data migration(PM, PP, MM, FI, CO, SD) SAP integration solution with SCT SAP ABAP development SAP smartforms and. As I have read I need to configure 2. AS2 Receiver config: Decryption Key: certificate generated in PI. as2. The SEEBURGER BIS Platform One central platform, one experience, all integrations, all deployment models. Check the MDN message that your system has received in SXMB_MONI. de DE-75015 Bretten Phone: +49 (0) 7252 96 1443 B2B Routing Service: AS2 Data Sheet (Without TLS/SSL) Technical information to configure your AS2 connection to the SEEBURGER Cloud DATA SHEET Company. RosettaNet connectivity allows RosettaNet messages to be sent and received using the HTTPS-based RosettaNet-specific protocol. Authentication Certificate: <Certificate of the Partner> AS2 Receiver Configuration. Seeburger Adapter - SAP PI7. Experienced in developing interfaces and maps; Well experienced in Client communication, gathering requirements. , SEEBURGER AS2: Negative synchron MDN received. Market Acceptance — Drummond Certified products that pass the test obtain the Drummond Certified seal and are put on the recommended AS2 vendor lists, recognizing your company’s support of industry standards and interoperability. In my experience, the renewal/replacement of AS2 certificates for encryption/decryption & signing/authentication requires coordinated effort on both sides. ssl. Stefan EDI stands for Electronic Data Interchange. 120 − 85. g. Message processing failed. ResourceException: Fatal. Hi, I'm doing one IDOC to AS2 Scenario. SEEBURGER Business Integration Suite (BIS) – Your Comprehensive Platform for Digital Transformation. 11 system. see burger, AS2, adapter, tls, 12, 11, inbound, outbound, , KBA , XX-PART-SEEB , Seeburger adapters for SAP Exchange Infrastructure , How To . Our scenario is outbound IDOC to AS2 (converted to EDIFACT). seeburger. seeburger-splitterreadable-log Naming recommendation seeburgerattachment_renamereadable-log seeburger-attribmapperreadable-log seeburger-dsig-readablelog seeburger-filestorereadable-log seeburger-splitter_modulereadable-log seeburger-secunetreadable-log seeburger-zip-readable-log. We are using the hostname in the Integration Direct, in receiver communication channel for example andSEEBURGER B2B Portal. Skip Step 3 and 4 by clicking the Finish button. Transport Protocol: HTTP. Create Datatype for EDI ANSI X12 850 structure: SEEBURGER AG AS2 Certificate Handling How To Guide Seite 6/21 19. There is no software patchwork. In EDI inbound scenarios (where PI delivers the EDI file to third party systems) using seeburger AS2, we request the MDN in synchronous mode. seeburger. ) which is not available in the existing Seeburger configuration. In the field Type, select AS2. With this experience I am able to work as a developer or lead any stage of an integration project and bring it to a successful end. We are using Seeburger AS2 receiver adapter, running SAP PI 7. A New Home in New Year for SAP Community: Exciting times ahead for the SAP Community!Not yet a member on the new home? Join today and start participating in the discussions!We have configured the scenario and it works as long as the partner only sends one message type (e. Market leading B2B/EDI integration platform used by 10,000 satisfied customers worldwide - expertise gained in 30 years in the business integration industry. I was trying to do a RFC -> XI -> Seeburger AS2 adapter (via HTTP) interface however I am running into problems. R. AS4's web services capability gives. The message is getting delivered but there is a fatal exception in the AS2 receiver adapter. The Functional Acknowledgment is mapped and converted as 997 data, which is sent back to. Earlier we have shared the connectivity details with the partner like seeburger url and other details, to access the same from partner side the credentials are not mandatory. Handling EDI interfaces using Seeburger BIC modules. resource. It is type of adapter while BIC is module. This, in turn, increases your company’s potential for new buyers. 3 version and SeeBurger AS2 adapter and I’m currently testing using my QA environment. Purpose The SEEBURGER EDIINT AS2 Adapter is responsible for transmitting files according to the AS2 protocol. g. 100% German-engineered from the ground up using a single source code base. 115. lang. *QATest. These solutions are for all industries. Hi, I'm trying to send a message to a partner using AS2, I've already defined the MDN and can see the message in SXMB_MONI pending. The API Solution for Powerful, Secure, Reliable Integration. A very obvious and important feature therefore expected out of Seeburger suite of products is complete monitoring of these files with most ease and comfort. de DE-75015 Bretten Phone: +49 (0)7252 96 1443 PEPPOL Access Service: REST Data Sheet Technical information to configure your. Learn more about the industry standards, data formats and templates the BIS Platform supports. U just have to configure SSL on java engine for which a single certificate would be required. 31 NWA. But the Network of our client is that huge that it seems to be nearly unmanageable to have an open connection from XI to the. Dear All, I have seen a changed AS2 adapter on PI 7. Over the years, AS2 has established itself in many industries; it has become the most widely used protocol in the retail and consumer goods industries. We've got SEEBURGER Business Integration Suite (BIS) because we needed an SFTP server. The SEEBURGER BIS is a fully cloud-native, modular integration technology stack that offers flexible deployment-ready solutions for your unique ecosystem. The SEEBURGER BIS API Solution ensures seamless connectivity between your business, your customers and partners, and the valuable data that runs your business. I've checked the AS2 Header message and I've got the following content: POST /as2/HttpReceiver Connection: Keep-Alive content-disposition: attachment; filename=1208788092268I have configured a FAck scenario as described by the Seeburger Manual and am testing a AS2 messaging scenario with a vendor (basically the inbound EDI message is passed to the Seeburger splitter to create a new message for the inbound order, and then the existing payload is mapped to a Funcational Acknowledgement and. The ID's are case sensitive. SEEBURGER AG AS2 Certificate Handling How To Guide Seite 7/21 19. , SEEBURGER AS2:. ssl. af. af. Reviewer Function Software Development. Learn more about TIE Kinetix EDI Solutions . ra. Name: SEEBURGER AG Name: SEEBURGER Cloud Service Team Address: Edisonstraße 1 E-mail: [email protected] DE-75015 Bretten Phone: +49 (0)7252 96 1443 B2B Routing Service: AS2 Data Sheet (High Security) Technical information to configure your AS2 connection to the SEEBURGER Cloud DATA SHEET Company Details Contact. The protocol was developed by the technical committee of OASIS (Organization for the Advancement of Structured Information Standards) for ebXML Messaging Services. Message processing. Setting up your company and user accounts as well as the configuration of your connection to the gateway in the SEEBURGER Cloud includes the following steps: Receiving an invitation email to register your company in the SEEBURGER Cloud. Reason: Fatal exception: javax. Exception: AS2 message composition failed:. SAP NetWeaver EDI Cross Industry Payment Adapter. SND >XI ->Webdispatcher--->A New Home in New Year for SAP Community: Exciting times ahead for the SAP Community!Depth knowledge and hands on experience in configuring SAP P(XI) adapters of FILE/FTP, IDOC, SOAP, HTTP, JMS, JDBC, MDM and RFC, RNIF, Seeburger & AS2 adapters along with protocols AS2, HTTPS,FTPS,SFTP. Use Identifiers tab to specify the agency and schema. Real Advantage. Problem getting unsigned MDN back on send to partner ruunning Seeburger. In Seeburger they have configured Archive beans as well and i wanted to know the. Hi. I've set on the. de DE-75015 Bretten Phone: +49 (0) 7252 96 1443 MBR Gateway Service: AS2 Data Sheet (Without TLS/SSL) Technical information to configure your AS2 connection to the SEEBURGER Cloud DATA SHEET Company. 0, E-Invoicing and ERP/SAP-Integration. KohlerNot yet a member on the new home? Join today and start participating in the discussions!Holding a Master's degree in Computer Science with a focus on E-Business & E-Governance. seeburger. Third Step: EDI940 it is Ansi X. Name: SEEBURGER AG Name: SEEBURGER Cloud Service Team Address: Edisonstraße 1 E-mail: support@cloud. Not yet a member on the new home? Join today and start participating in the discussions!Mar 2014 - Aug 2014. 2013 Fill in the Subject Properties. 1. Sender & Receiver IDs refers to the partner’s ID. Our BIS Platform enables seamless connectivity of applications, people and processes, whether in the cloud, a hybrid environment or on-premises. Overview. Our BIS Platform enables seamless connectivity of applications, people and processes, whether in the cloud, a hybrid environment or on-premises. I have already identified that SAP provides 2 different solutions for this requirement - SAP B2B Add-on & SAP Secure Add-on. Hinweis: Wir empfehlen. de DE-75015 Bretten Phone: +49 (0) 7252 96 1443 Supplier Portal Service: AS2 Data Sheet (Without TLS/SSL) Technical information to configure your AS2 connection to the SEEBURGER Cloud DATA SHEET Company. I am finding difficulty in handling the HL. Seeburger's documentation says possible causes are: 1) You or your partner have entered an incorrect AS2 ID for one of the involved parties. Reason: Fatal exception: javax. I have imported DtReport for MDN's from SeeBurger AS2 adapter documentation as external definition into PI. And for these scenarios, we are using the AS2 adapter (for sender or receiver channel configuration) . apache. javax. I have a scenario which is connecting with third party using sender AS2 adapter but every time the third party sends a message to PI they are getting 403 forbidden. 3. R/3 is in our landscape, its component created without Party. As per the. 5 and has worked on interfaces using adapters like File, IDoc, SOAP, JDBC, XI, RFC, Seeburger AS2, SFTP, HTTP, Mail, SOAP Axis, REST Experience working with Axway suite of Integration products like B2Bi, API Gateway, Sentinel, Gateway Interchange, Activator, Secure TransportAppliance manufacturer taps SEEBURGER EDI technology to advance SAP NetWeaver and UCCnet initiatives. The AS2 subject has to be dynamic and depends on a particular node in the incoming message. I am attempting to send a flat file using Seeburger's AS2 adapter. Detailed release information can be found in note 890721, 890722. As per seeburger: – Outgoing HTTPS connections for HTTP based SEEBURGER adapters (e. There are many ways to deploy the. Also, the modules for "handling the EDI data" which are. Regards. Dear all, I would like to send out a message via AS2 (Seeburger Adapter). The Seeburger PI adapter alternative with the most benefits is a migration to a cloud. xi. e. I am working on a scenario for sending EDI transactions to our external customer using AS2 Adapter from Seeburger. resource. Both protocols are used by a large number of customers. ) are based on the standard security providers of the underlying Java VM (usually the provider. In the last 20 years, AS2 has become the. - Management of internal projects in the Cloud Service team. Reduce time, effort and reliance on IT staff with pre‑packaged industry content, templates, mappings and connectors. Any idea ? What is the meaning of "no signature certificate" ? Because we import the certificate info the Trustcenter form the partner and customized in . AS2 Receiver Configuration -> Encryption Certificate. - Monitoring of individual and team projects. RSS Feed. 1 Answer. Configuring the Seeburger Message Splitter Using Seeburger Workbench. In case of EDI, we use Seeburger adapter in XI. 4. We are a third-party logistics company. SAP PO B2B Inbound AS2. 03. I am using AS2 Rece Channel with HTTPS Transport Protocol. First we need to setup the sending partner details. Experienced in developing interfaces and maps; Well experienced in Client communication, gathering requirements. It will have a description of what was the issue. This. We have a process in GIS system to pick the file from PI Server and do the mapping and post the output data to ORD System. In AS2 receiver I have protocol. After you have finished the configuration of your EDI system, you can start testing your configuration. Not yet a member on the new home? Join today and start participating in the discussions!AS2 Sender Configuration. Introduction SAP Netweaver Providing infrastructure of B2B Seeburger and B2B Adapters EDI Content Configuration Message Monitoring and Security Summary. With PI 7. Select FILE for Type, and then click Configure. OFTP2. To separate such direct connections for different customers, systems and protocols, different ports. aii. However, I've bumped at the point when I was creating the sender communication channel. With the BIS Platform, anyone can design simple to complex integrations on their own, helping to strengthen their company's digital ecosystem. I’m using PI 7. 120 − 1. config. Our BIS Platform enables seamless connectivity of applications, people and processes, whether in the cloud, a hybrid environment or on-premises. This online Edi system offers AS2 Capability, Data Format Translation, Document Archiving, EDI Testing, Reporting/Analytics at one place. Hi, SOAP to AS2 interface. 1 Supplier, called “Seeburger” that receives the orders from both partners and processes. Option 2. Functional Acknowledgment. Over the years, AS2 has established itself in many industries; it has become the most widely used protocol in the retail and consumer goods industries. We are a third-party logistics company. 0. A New Home in New Year for SAP Community: Exciting times ahead for the SAP Community!Seeburger, AS2 and SFTP configuration and support. 100% German-engineered from the ground up using a single source code base. As of now, i haven't received any message into AS2 Sender channel. This interface is working fine, until certificate isPlease check with your AS2 partner about the details of not able to process the document. The setting i have made during configation are : 1> Reciver Party with Agency,Schema and Name entered. Thanks. I think SAP should have used the 1049845 - How to use custom security providers when implementing the SAP PI B2B addon with sftp/pgp/as2, the same applies to the seeburger as2 adapters, aedaptive pgp and others, instead the mentioned adapters are incompatible and can't reside in the same server. SEEBURGER previously was the first EDI technology provider with an AS2 solution, which was used to turn the Hyundai Motor Company factory in Alabama into the first AS2-only automotive plant when. However AS2 without client cert auth is working with SeeBurger too. • Worked on SAP PI 7. seeburger. The payload was delivered from cyclone end but the receipt (MDN) obtained. SEEBURGER Certified Adapters for SAP Netweaver Process Integration (PI): SAP NetWeaver Generic EDI Adapter. 4. You need to overwrite Sender Party with the your Organization party (which has identifiers, so that the receiver can understand that the message was sent by your organization) in the receiver agreement. Our scenario is outbound IDOC to AS2 (converted to EDIFACT). Also, configure the message splitter configuration within the Seeburger Workbench. 19. Cause: javax. SEEBURGER Cloud – B2B Routing Service – Datasheet AS2 (High Security) To use AS2, you need to import the certificates of the SEEBURGER Cloud. seeburger. We are using Seeburger AS2 adapter for AS2 communication in SAP PI 7. AS2, HTTP, EbXML_HTTP) and incoming/outgoing SSL/TLS connections of non-HTTP SEEBURGER adapters (e. BIC is a module and BIS is a separate middleware provided by Seeburger just like PI. 1 Seeburger AS2 adapter. SEEBURGER & SAP ® a strong partnership for more than 20 years SEEBURGER has been a longstanding partner of SAP. Real Experience. the configurations multiple times and everything look to be. de DE-75015 Bretten Phone: +49 (0)7252 96 1443 MaKo Cloud Service: AS2 Data Sheet (High Security) Technical information to configure your AS2 connection to the SEEBURGER Cloud DATA SHEET Company Details. These parameters have already been explained in the Scenario 1 and the literal meaning remain the same. 1 Supplier, called “Seeburger” that receives the orders from both partners and processes. However, they cannot processed the payload as they claim there are concatenation of strings after content-type. This is the place where you may come to know whether requested MDN is received by Seeburger or not. ResourceException: SEEBURGER AS2: AS2 Adapter failure # Outbound configuration error: Failed to get configuration from DATABASE. I’m using PI 7. We are using the Seeburger AS2 adapter in our landscape and I am in the process of setting the same up and have made quite some progress in all my issues. 1. SAP NetWeaver Technical EDI Adapter for VAN Access. 40 years on and with the advent of the Internet, the. 03. , Please do need full ASAP. 0/7. seeburger. 2. ORDER-XML). Since the customer sends it via AS2 server, we will configure Seeburger provided AS2 sender adapter to solve our purpose. The involved companies and their B2B partners take care of the data collection. It is. Mapping Tools: IBM Sterling B2B Integrator 8. In addition to our technical capabilities and the certification of our Peppol Services for Japan, it is essential to understand the culture, language, businesses, market and tax regulations in Japan in order to support our clients best. the default HTTP port of the SEEBURGER AS2 adapter for SAP XI is 50000. The protocol was developed by the technical committee of OASIS (Organization for the Advancement of Structured Information Standards) for ebXML Messaging Services. edi. When i tried to sign it, the channel is giving the following error. 100% German-engineered from the ground up using a single. In the field AS2 ID, provide the AS2 identifier for your technical connection. Verdict: With SEEBURGER, you will get a comprehensive solution for integrating technical partners of any size. We have sent them our certificate chain having our public certificate in . seeburger. The Seeburger AS2 adapter will receive the 850 EDI file and it will be split into Order (XML file) and. Reason: Fatal exception: com. The SEEBURGER Business Integration Suite is a full, single-source solution with modular services which you can book and combine as and how you need them. resource. Hence if you have more than one. Activity Agree? Agree? Liked by Anushri Mishra. Configured Seeburger AS2 adapter to send and receive EDI messages Configured EDI to Idoc scenarios to convert Truck EDI invoices (210) and Rail EDI invoices (410) to Invoic Idoc and configured 997 Functional acknowledgements . 1, 7. We will now have a look at the few resources provided by SAP with regards to. Creator: jll Created: 2019-03-08 Updated: 2019-03-11 jll - 2019-03-08 Hi,. The EDI Sales Order message processes perfectly, resolves to the correct BIC Child Mapping, maps. Skip to Content. Hello all, I want to send AS2 messages using the Seeburger adapter, but get the following error Unable to forward message to JCA adapter. We have a lot of customers at various levels of IT maturity. java:321). In the XML message monitoring there are two payload messages: In the message RAWMIMEMDN I see the header data and also the DATE field, now the. E. v. If required, properties can be added or removed by clicking the Add or Remove button. Please note that all the fields are case sensitive. Why Enabling Business-to-Business Processes? B2B. cloud. ) or as an on-premises software solution. ResourceException: Fatal exception: com. It is from R/3 --> PI --> Third Party. 0. 0, E-Invoicing and ERP/SAP-Integration. To create a new AS2 cloudlink, follow these steps: Open the app B2B Directory. Request async MDN (Not signed) by provided our HTTPS AS2 URL in receipt delivery address, no MDN time out. ResourceException: SEEBURGER AS2: org. Hello all, if we try to sent a message through Seeburger AS2 Adapter we get back follow error: Message could not be forwarded to the JCA adapter. My belief is that OpenAS2 is only willing to accept an HTTP status code of 200 in response to the POST request it sends. cloud. 1. 31, PO 7. Has anybody faced this specific scenario? This is not really a Biztalk issue but the client cert auth issue between SeeBurger & IIS. 0, Sterling Integrator 5. For instance is AS2 Partner number on the B2B Add-on adapter where seeburger is using the attribute from the parties selected. 2) A firewall is blocking the communication with the web server. 3. 1. Sep 2013 - Nov 2017 4 years 3 months. Message Protocol: AS2. Preventing errors as data is generated automatically by the system w/o human interaction. Message Protocol: AS2. Aug 14, 2010 at 07:36 PM. 5. cci. S. Forum: Compatibility. Yes Srinivas. We have been informed from one of our customer/partner that they have changed the IP address at their end. cloud. 3. The user of the client should talk to their software provider to see if it is capable of sending the signature_algorithms extension. Where we are posting the IDOC successfully, but we are not able to receive the message. Configured CMS for transporting Integration Builder components; Alert configuration performed for Runtime Workbench environment; Maintained the three system landscape for PI, Performance tuning and. Option 3. 4) The Job of Splitter module is to create as many XML messages as there are headers according to the EDI (format)you are using. First one, checking the messages in Seeburger monitoring and looking for erroneous entry which was displayed as below: All the fields of monitoring are not shown here however, the most important part here is the symbol "i" on extreme right which. 2013 Fill in the Subject Properties. The EDI solution must support. I passed some messages via cyclone to Seeburger AS2 adapter which is being configured in SAP XI. Regards, Chakrapani. Avoid the complexities. For EDI handling there is also some differences. However we get a message u201CFatal exception: javax. e. Make sure you and your partner has entered exactly the same AS2ID in the configuration. Reduce time, effort and reliance on IT staff. The SEEBURGER solutions for SAP complement the BIS platform and bring transparency in the booking process in SAP. X version of Seeburger has evolved which incorporated the adapter engine specific changes that are required with PI 7. >>is AS2 adapter is part of BIS or BIC. We are trying to establis a B2B AS2 connection with a Partner (outside the network). Integration of EDI transactions into ERP Systems like SAP R/3. I have put SSL Certificate (keystore) value. Also we don't receive any messages via AS2 anymore. seeburger. There is a lot of fuss around the Split adapter of Seeburger. Cause: javax. ValidatorException: No trusted certificate found # null The AS2 of the third party is also their SSL certificate. > Registering in the SEEBURGER Customer Portal via a registration link. AS2 is a protocol based on to transmit messages to business partners quickly, cheaply, securely and reliably. Dear Experts- I have a production issue with one of the scenario in which we use AS2 adapter is used to receive the message. 31, PO 7. For the EDIFACT, X12 messages the XSD structures is a little different, because some elements have been renamed and changed position. Possible Solution: Check if the system is able to resolve the name of the remote host using nslookup <host name> or ping <hostname> (pings are often blocked by firewalls!). seeburger. Hi. Replace the EDI VAN. This holistic approach allows for a comprehensive, secure solution during the entire API lifecycle, from creation through publication to management of in-house and business partner APIs. RosettaNet connectivity supports the versions RNIF 1. Although there were certain blogs present on SDN explaining how to use Split module, there wasn’t very clear explanation as where exactly this Split module is used and during a message flow, when does it gets executed. 115. Usage of the AS2 communication protocol in the real world. As new buyers examine products on the. Industry Specific EDI adapters. SSLHandshakeException: sun. seeburger. In a. In this Seeburger BIC mapper we have the standard mapping which can convert the EDI to XML format and. 1 ServiceProvider called “RetailHub” which sends data for both customers through one AS2-Connection. So its component created. The AS2 spec, as I recall, states that any 200 series status code should be treated as an acceptance of the POST request. seeburger. I have read that standard ALM alerts can be set up in PI and configured to trigger in the comm channel settings. please check. We work for a lot of people. Initially we have PI7. cer format.